1.General Introduction

ABB 266MST differential pressure transmitter is a traditional type for differential pressure measurement, measure range from -10Mpa to 10Mpa, maximum static pressure is up to 60Mpa and maximum turn down ratio up to 100:1, standard accuracy is 0.04%, meets SIL2,SIL3 safety applications as per IEC 61508 standard. Accordingly to customer requests, it can either be integrated to five way or three way M26 manifold, or remote connection to manifold via impulse line.

2.Measuring Span & Range Limits

Sensor Code

Lower Range Limit (LRL)

Upper Range Limit (URL)

Standard TD Ratio

Max. TD Ratio

Standard Static Pressure

A

-1Kpa, -10mbar, -4inH2O

1Kpa, 10mbar, 4inH2O

10:1

20:1

2Mpa, 20bar, 290psi

C

-6Kpa, -60mbar, -24inH2O

6Kpa, 60mbar, 24inH2O

10:1

30:1

60Mpa, 600bar, 8700psi

F

-40Kpa, -400mbar, -160inH2O

40Kpa, 400mbar, 160inH2O

10:1

100:1

60Mpa, 600bar, 8700psi

L

-250Kpa, -2500mbar, -1000inH2O

250Kpa, 2500mbar, 1000inH2O

10:1

100:1

60Mpa, 600bar, 8700psi

N

-2000Kpa, -20bar, -290psi

2000Kpa, 20bar, 290psi

10:1

100:1

60Mpa, 600bar, 8700psi

R

-10000Kpa, -100bar, -1450psi

10000Kpa, 100bar, 1450psi

10:1

100:1

60Mpa, 600bar, 8700psi

3.Ambient & Process Temperature Limits

Oil filling & sensor range

Ambient temperature limits

Process temperature limits

Silicone oil

-40 and 85℃  (-40   and 185℉)

-40 and 121℃  (-40   and 250℉)

Inert (Galden)

-40 and 85℃  (-40   and 185℉)

-40 and 121℃  (-40   and 250℉)

Maximum operating pressure (60 MPa, 600 bar, 8700 psi)

-20 and 70℃  (-4 and   158℉)

-20 and 85℃  (-4 and   185℉)

With LCD integral display

-40 and 85℃  (-40   and 185℉)

N/A

Viton gasket

-20 and 85℃  (-4 and   185℉)

-20 and 121℃  (-4   and 250℉)

PTFE gasket

-20 and 85℃  (-4 and   185℉)

-20 and 85℃  (-4 and   185℉)


4.Basic Code Selection of 266MST Differential Pressure Transmitter

Main Code

Suffix Codes

Description

266MST








Differential pressure transmitter, base accuracy 0.04 %

SENSOR - Span Limits

A







0.05 and 1 kPa   (0.5 and 10 mbar, 0.2 and 4 in. H2O), "Vx" option is required

C







0.2 and 6 kPa   (2 and 60 mbar, 0.8 and 24 in. H2O)

F







0.4 and 40 kPa   (4 and 400 mbar, 1.6 and 160 in. H2O)

L







2.5 and 250   kPa (25 and 2500 mbar, 10 and 1000 in. H2O)

N







20 and 2000   kPa (0.2 and 20 bar, 2.9 and 290 psi)

R







100 and 10000   kPa (1 and 100 bar, 14.5 and 1450 psi)

Maximum Working Pressure


Y






1 MPa / 10 bar   / 145 psi (Only available with Process Flanges code P)


W






Differential   measurement at high static pressure


C






Gauge measurement


Z






25 MPa / 250   bar / 3625 psi (Not available with Sensor Span Limits code A)


T






41 MPa / 410   bar / 5945 psi (Not available with Sensor Span Limits code A)


A






60 MPa / 600 bar / 8700 psi (Not   available with Sensor Span Limits code A, only with process

connection   code A)

Diaphragm Material / Fill Fluid



S





AISI 316L SST   (1.4435) / Silicone oil (NACE)



K





Hastelloy C–276   / Silicone oil (NACE)



M





Monel 400 /   Silicone oil (NACE)



V





Monel 400 gold–plated   / Silicone oil (NACE)



T





Tantalum /   Silicone oil (NACE)



A





AISI 316L SST   (1.4435) / Inert fluid – Galden (Suitable for oxygen applications) (NACE)



F





Hastelloy C–276   / Inert fluid – Galden (Suitable for oxygen applications) (NACE)



C





Monel 400 /   Inert fluid – Galden (Suitable for oxygen applications) (NACE)



Y





Monel 400 gold–plated   / Inert fluid – Galden (Suitable for oxygen applications) (NACE)



D





Tantalum /   Inert fluid – Galden (Suitable for oxygen applications) (NACE)

Process Flanges and Adapters Material/ Connection




A




AISI 316L SST   (1.4404 / 1.4408) / 1/4–18 NPT female direct (horizontal connection) (NACE)




B




AISI 316L SST (1.4404 / 1.4408) / 1/2–14   NPT female through adapter (horizontal connection)

(NACE)




C




AISI 316L SST (1.4404 / 1.4408) / 1/4–18   NPT female direct (DIN 19213) (horizontal

connection)   (NACE)




D




Hastelloy C–276   / 1/4–18 NPT female direct (horizontal connection) (NACE)




E




Hastelloy C–276   / 1/2–14 NPT female through adapter (horizontal connection) (NACE)




G




Monel 400 /   1/4–18 NPT female direct (horizontal connection) (NACE)




H




Monel 400 /   1/2–14 NPT female through adapter (horizontal connection) (NACE)




P




Kynar (PVDF) /   1/4–18 NPT female direct (MWP = 1 MPa) (insert on side of flange)




Q




AISI 316L SST   (1.4404 / 1.4408) / 1/4–18 NPT female direct (vertical connection) (NACE)

Bolts Material/ Gaskets Material





3



AISI 316 SST   (NACE – not exposed to H2S) / Viton (Suitable for oxygen applications) (Max.   41 MPa / 410 bar / 5945 psi)





4



AISI 316 SST   (NACE – not exposed to H2S) / PTFE (Max. 25 MPa / 250 bar / 3625 psi)





5



AISI 316 SST   (NACE – not exposed to H2S) / EPDM (Max. 41 MPa / 410 bar / 5945 psi)





6



AISI 316 SST   (NACE – not exposed to H2S) / Perbunan





7



AISI 316 SST   (NACE – not exposed to H2S) / Graphite (Max. 41 MPa / 410 bar / 5945 psi)





T



AISI 316 SST /   FEP (Only available with Kynar [PVDF] process connection)

Housing Material / Electrical Connection






A


Aluminum alloy (Barrel type) / 1/2–14 NPT






B


Aluminum alloy (Barrel type) / M20 x 1.5






E


Aluminum alloy (Barrel type) / Harting Han connector (General purpose   only)






G


Aluminum alloy (Barrel type) / Fieldbus connector (General purpose only)






S


AISI 316L SST (Barrel type) / 1/2–14 NPT (I2 or I3 required)






T


AISI 316L SST (Barrel type) / M20 x 1.5 (I2 or I3 required)






J


Aluminum alloy (DIN type) / M20 x 1.5






K


Aluminum alloy (DIN type) / Harting Han connector (General purpose only)






W


Aluminum alloy (DIN type) / Fieldbus connector (General purpose only)






Z


AISI 316L SST (Barrel type) / Fieldbus connector (General purpose only)

Output







1

HART digital   communication and 4 to 20 mA







2

Profibus PA







3

Foundation fieldbus







8

HART digital   communication and 4 to 20 mA, SIL2 and SIL3 certified to IEC 61508

Optional Codes

/Optional codes


5.Basic Code Selection of M26 Manifolds

Main Code

Suffix Codes

Description

M26















Manifold model for 266   Pressure Transmitters

Design

D














Manifold for DP   Style transmitters

P














Manifold for P   Style transmitters

Revision


A













Revision A

Body configuration



S












Standard construction



V












For vertical-flange   transmitter

Valves




2











Two-valve   manifold




3











Three-valve   manifold




5











Five-valve   manifold

Valve type





V










Standard

Material (wetted parts)






S









AISI   316L SS, NACE






H









Hastelloy   C276, NACE






M









Monel   400






N









Inconel   625

Packing material







P








PTFE







G








Graphoil

Gasket material   (wetted parts)








N







None








P







PTFE








G







Graphoil

Manifold process   connection (INLET)









F






Threaded 1/2 in. - 14   NPT-female









M






Threaded 1/2 in. - 14   NPT-male

Manifold   transmitter connection (OUTLET)










1





Flanged outlet   according to IEC61518/B










F





Threaded 1/2 in. - 14   NPT-female










M





Threaded 1/2 in. - 14   NPT-male

Rating











6




413.7 bar (41.37MPa,   6000 psi)











1




690 bar (69MPa, 10000   psi)

Transmitter   fixing bolts












N



None












C



Carbon Steel












S



Stainless Steel NACE   compliant (MWP=21MPa, 210 bar, 3045 psi)

Bracket kit













N


None













C


Carbon Steel













S


Stainless Steel NACE   compliant (MWP=21MPa, 210 bar, 3045 psi)

Material   traceability














2

Inspection certificate   EN 10204–3.1 of process wetted parts

Optional codes

/Optional codes